Sand and Dust Test Chamber/Dust Test Chamber/Sand and Dust Testing
Features
● Dust concentration monitoring: real-time monitoring of dust concentration, and automatic dust replenishment according to concentration changes
● Dust blowing direction: automatic switching of dust blowing direction
● Test time: dust blowing time (stop, blow) automatically alternates, 1s-9999min adjustable; vibration time (vibration and stop) automatically alternates, 1s-9999min adjustable; preset test time 0~99h59min adjustable; test wind speed: (1m~10m)/s adjustable
● Equipped with an advanced circulation and dust filtration system to maintain consistent test conditions throughout the chamber
● Built with durable materials and advanced design to provide a stable, reliable testing environment with long service life
Product specification
Technical Parameters
| Model | SWC-500 | SWC-800 | SWC-1000 | SWC-1500 |
| Workshop size (mm) | 800*800*800 | 800*1000*1000 | 1000*1000*1000 | 1000*1500*1000 |
| Metal screen nominal wire diameter | 50μm | |||
| Nominal spacing between wires | 75μm | |||
| Air flow velocity | 2m/s | |||
| Inlet pressure control | Adjustable flow meter | |||
| Standard dust volume in the box | 2Kg/m3~4Kg/m3 | |||
| Inner liner material | High-grade stainless steel plate | |||
| Standard configuration | Glass door with dust brush, stainless steel sample rack, Φ50mm standard lead hole | |||
| Complies with standards | GB2423.37、GB2423.38、GB2424.23、GB4208.2008 | |||
| Note: The sand and dust series equipment is suitable for shell sealing and internal dustproof tests of various products and components | ||||
Model parameters
| Diameter of metal mesh wire | 50μm | |
| Nominal spacing | 75μm | |
| Amount of talcum powder | (2kg~4kg)/m3 | |
| Fighting time | 0~99H59M | |
| Blower cycle time | 0~99H59M | |
| size | Studio | 1000x1000x1000(WxHxD)mm |
| Outer box | 1550x1800x1400(WxHxD)mm | |
| Data logging | It has a battery-protected RAM that can save the device's set values, sampling values, and sampling time; the recording time is no less than 120 days (sampling cycle 2 minutes) | |
| Additional functions | It has a battery-protected RAM that can save the device's set values, sampling values, and sampling time; the recording time is no less than 120 days (sampling cycle 2 minutes) Fault alarm and cause, processing prompt function Power-off protection function Upper and lower temperature limit protection function Calendar timing function (automatic start and automatic stop operation) Self-diagnosis function. |
|
Product Structure